Working form P10

Wastewater Authorization and Disposal Record

Establish the lawful route before generating wash water.

Keep this neutral blank master and save a separate dated working copy for your own business or job. Record the job ID, date, version and responsible person.

The separately completed example is fictional. It documents no physical test, real customer, insurance determination, registration or utility approval obtained by this course. Use actual current evidence in real work.

Enter explicit zeros or not applicable only when verified; leave unresolved matters clearly marked HOLD with a responsible action and review date.

Your repeatable records

Add one blank record for each item you need to track. These entries belong to this form and this browser.

Recovery and disposal batch log

Record each completed recovery-and-transfer batch, its volume, control checks, entire approved receiving path and residual solids disposition. Record actual equipment/fixture geometry, individual handled loads, transfer count and allowed flow rate before starting.

Show a separate fictional recovery and disposal batch log example
Simulated day / batch / elapsed time
SIMULATED Day 0 B01; transfer completed T + 65 min
Simulated gallons, not measured
7.5 gal; 7 full + 1 half jug cycles
Stipulated recovery check
Washer stopped/pressure released; vacuum off/unplugged; supported low-tray drain; refit/check before restart
Assumed approved receiving route
AUTH-P-01: tray → handled scoop → capped jug → R01; full pours ≥30 sec, half ≥15 sec; assumed ≤2 GPM
Simulated discharge / solids record
Accepted in story; no overflow. S01 screenings to SW03; 8 cycles
Simulated day / batch / elapsed time
SIMULATED Day 0 B02; transfer completed T + 80 min
Simulated gallons, not measured
7.5 gal; 7 full + 1 half jug cycles
Stipulated recovery check
Washer stopped/pressure released; vacuum off/unplugged; supported low-tray drain; refit/check before restart
Assumed approved receiving route
AUTH-P-01: tray → handled scoop → capped jug → R01; full pours ≥30 sec, half ≥15 sec; assumed ≤2 GPM
Simulated discharge / solids record
Accepted in story; no overflow. S01 screenings to SW03; 8 cycles
Simulated day / batch / elapsed time
SIMULATED Day 0 B03; transfer completed T + 95 min
Simulated gallons, not measured
7.5 gal; 7 full + 1 half jug cycles
Stipulated recovery check
Washer stopped/pressure released; vacuum off/unplugged; supported low-tray drain; refit/check before restart
Assumed approved receiving route
AUTH-P-01: tray → handled scoop → capped jug → R01; full pours ≥30 sec, half ≥15 sec; assumed ≤2 GPM
Simulated discharge / solids record
Accepted in story; no overflow. S01 screenings to SW03; 8 cycles
Simulated day / batch / elapsed time
SIMULATED Day 0 B04; transfer completed T + 110 min
Simulated gallons, not measured
7.5 gal; 7 full + 1 half jug cycles
Stipulated recovery check
Washer stopped/pressure released; vacuum off/unplugged; supported low-tray drain; refit/check before restart
Assumed approved receiving route
AUTH-P-01: tray → handled scoop → capped jug → R01; full pours ≥30 sec, half ≥15 sec; assumed ≤2 GPM
Simulated discharge / solids record
Accepted in story; no overflow. S01 screenings to SW03; 8 cycles
Simulated day / batch / elapsed time
SIMULATED Day 0 B05; transfer completed T + 125 min
Simulated gallons, not measured
7.5 gal; 7 full + 1 half jug cycles
Stipulated recovery check
Washer stopped/pressure released; vacuum off/unplugged; supported low-tray drain; refit/check before restart
Assumed approved receiving route
AUTH-P-01: tray → handled scoop → capped jug → R01; full pours ≥30 sec, half ≥15 sec; assumed ≤2 GPM
Simulated discharge / solids record
Accepted in story; no overflow. S01 screenings to SW03; 8 cycles
Simulated day / batch / elapsed time
SIMULATED Day 0 B06; transfer completed T + 140 min
Simulated gallons, not measured
7.5 gal; 7 full + 1 half jug cycles
Stipulated recovery check
Washer stopped/pressure released; vacuum off/unplugged; supported low-tray drain; refit/check before restart
Assumed approved receiving route
AUTH-P-01: tray → handled scoop → capped jug → R01; full pours ≥30 sec, half ≥15 sec; assumed ≤2 GPM
Simulated discharge / solids record
Accepted in story; no overflow. S01 screenings to SW03; 8 cycles
Simulated day / batch / elapsed time
SIMULATED Day 0 B07; transfer completed T + 155 min
Simulated gallons, not measured
7.5 gal; 7 full + 1 half jug cycles
Stipulated recovery check
Washer stopped/pressure released; vacuum off/unplugged; supported low-tray drain; refit/check before restart
Assumed approved receiving route
AUTH-P-01: tray → handled scoop → capped jug → R01; full pours ≥30 sec, half ≥15 sec; assumed ≤2 GPM
Simulated discharge / solids record
Accepted in story; no overflow. S02 screenings to SW03; 8 cycles
Simulated day / batch / elapsed time
SIMULATED Day 0 B08; transfer completed T + 170 min
Simulated gallons, not measured
7.5 gal; 7 full + 1 half jug cycles
Stipulated recovery check
Washer stopped/pressure released; vacuum off/unplugged; supported low-tray drain; refit/check before restart
Assumed approved receiving route
AUTH-P-01: tray → handled scoop → capped jug → R01; full pours ≥30 sec, half ≥15 sec; assumed ≤2 GPM
Simulated discharge / solids record
Accepted in story; no overflow. S02 screenings to SW03; 8 cycles
Simulated day / batch / elapsed time
SIMULATED Day 0 B09; transfer completed T + 185 min
Simulated gallons, not measured
7.5 gal; 7 full + 1 half jug cycles
Stipulated recovery check
Washer stopped/pressure released; vacuum off/unplugged; supported low-tray drain; refit/check before restart
Assumed approved receiving route
AUTH-P-01: tray → handled scoop → capped jug → R01; full pours ≥30 sec, half ≥15 sec; assumed ≤2 GPM
Simulated discharge / solids record
Accepted in story; no overflow. S02 screenings to SW03; 8 cycles
Simulated day / batch / elapsed time
SIMULATED Day 0 B10; transfer completed T + 200 min
Simulated gallons, not measured
7.5 gal; 7 full + 1 half jug cycles
Stipulated recovery check
Washer stopped/pressure released; vacuum off/unplugged; supported low-tray drain; refit/check before restart
Assumed approved receiving route
AUTH-P-01: tray → handled scoop → capped jug → R01; full pours ≥30 sec, half ≥15 sec; assumed ≤2 GPM
Simulated discharge / solids record
Accepted in story; no overflow. S02 screenings to SW03; 8 cycles
Simulated day / batch / elapsed time
SIMULATED Day 0 B11; transfer completed T + 215 min
Simulated gallons, not measured
7.5 gal; 7 full + 1 half jug cycles
Stipulated recovery check
Washer stopped/pressure released; vacuum off/unplugged; supported low-tray drain; refit/check before restart
Assumed approved receiving route
AUTH-P-01: tray → handled scoop → capped jug → R01; full pours ≥30 sec, half ≥15 sec; assumed ≤2 GPM
Simulated discharge / solids record
Accepted in story; no overflow. S02 screenings to SW03; 8 cycles
Simulated day / batch / elapsed time
SIMULATED Day 0 B12; transfer completed T + 230 min
Simulated gallons, not measured
7.5 gal; 7 full + 1 half jug cycles
Stipulated recovery check
Washer stopped/pressure released; vacuum off/unplugged; supported low-tray drain; refit/check before restart
Assumed approved receiving route
AUTH-P-01: tray → handled scoop → capped jug → R01; full pours ≥30 sec, half ≥15 sec; assumed ≤2 GPM
Simulated discharge / solids record
Accepted in story; no overflow. S02 screenings to SW03; 8 cycles
Simulated day / batch / elapsed time
SIMULATED Day 0 B13; transfer completed T + 265 min
Simulated gallons, not measured
4 gal; 4 full jug cycles
Stipulated recovery check
Washer stopped/pressure released; vacuum off/unplugged; supported low-tray drain; refit/check before restart
Assumed approved receiving route
AUTH-P-01: tray → handled scoop → capped jug → R01; full pours ≥30 sec, half ≥15 sec; assumed ≤2 GPM
Simulated discharge / solids record
Accepted in story; no overflow. S02 screenings to SW03; 4 cycles

Completed practice examples

These filled records use fictional teaching inputs and observations. Replace them with evidence for your own job.

P10 SIMULATED completed example

Fully populated fictional teaching record. Every person, permission, authorization, reading, observation, event and result below is stipulated for this simulation only. No real customer, site visit, physical test, practical qualification, payment or permit is represented; this is not the learner’s completed record.

Job authority and drainage map
SIMULATED P-FIRST-01/P10-v 1, Day 0, CASE OWNER, site token SIM-SITE-VAN-01 in fictional Vancouver, Washington. Drain map M01 has D01 and P01 inside the private boundary, a bermed low collection edge, protected storm inlet ST01 and a public route outside the work zone. ST01, street, lawn and septic routes receive 0 simulated washwater.
Waste stream and proposed route
Assumed waste stream: ordinary assessed concrete soil in cold water, with no added cleaner, oil sheen, paint residue or hazardous material. The simulation stipulates 94 gal recovered: 90 gal theoretical washer output (36 assumed trigger-on minutes × rated 2.5 GPM) plus 4 gal purge/rinse. These are constructed teaching quantities, not measured consumption or a validated recovery yield. The clean inlet-flow test is separate.
Prior written approval and conditions
SIMULATED application record: initial customer/site/contaminant/drainage/receptor records Day −14; operator application Day −12; clarification Day −8; assumed written AUTH-P-01 Day −4; detailed remote confirmation Day −3, before offer/acceptance Day −2. This invented sequence guarantees no authority response time. AUTH-P-01 names this water-only stream, private sanitary utility sink R01 and owner permission RP-P-01. Assumed conditions include full capture, accepted external sediment screening, the low-tray/scoop/jug route below, controlled attended pouring at no more than 2 GPM, no overflow/splash or hazardous/chemical stream, and segregated solids. The maximum rate is a fictional site-specific condition, not a Vancouver or Portland general rule. No real authority issued this course a permit.
Containment recovery capacity and stops
SIMULATED BM01 capture feeds HD1800 on its factory cart: dry paper filter removed for larger liquids, VF7000 wet foam fitted and cage/float retained on the powerhead, with dry protected power and no rain. Assumed working mark is 8 gal; B01–B12 each contain 7.5 gal and B13 contains 4 gal. Stop washing, release stored pressure safely and switch the vacuum off/unplug it. With drain cap secured, move the loaded cart only over the assumed clear level route of no more than 20 ft to the contained transfer station; no stairs. Following SP7157 Figure 13, position beside the suitable low receptacle, remove drain cap, pull the top of both latches outward, lift off the powerhead and set it aside clean, dry and safely supported. Gravity-drain into the stationary low tray with the drum remaining floor-supported; no loaded drum or tray is lifted or tilted. Refit powerhead, latches and drain cap, and check assembly before cart return/restart. The manual handling warning requires scooping/draining to a comfortable load before any lift; this case makes no loaded lift at all. Actual fit, capacity and handling remain unverified.
Transfer geometry and handled load
SIMULATED station: HD1800 drain lower lip 4 in above floor; tray rim 3 in, internal base 36 × 30 in, stipulated rated capacity at least 10 gal and working limit 8 gal. A 0.5-gal handled scoop fills a 1.5-gal closable handled jug marked at a one-gallon working maximum. Tray remains stationary on the floor inside containment. Sink R01 rim is 34 in high with a clear level two-foot jug-transfer path and no steps. One full jug contains 1 gal × 8.34 lb/gal + 1.2 lb tare = 9.54 lb; a half-gallon jug is 5.37 lb. Close the jug for carrying, open only for the controlled attended pour, and reduce loads further if individual capacity requires it. There is no pump pushing uphill, no full-drum/tray lifting and no assertion that these invented dimensions or loads are suitable for a real person/site.
Disposal and residual solids records
Completed SIMULATED log P10-1: B01–B13 total 94 gal, gravity-drained to the low tray and transferred through the handled scoop/jug to R01 under AUTH-P-01. Twelve 7.5-gal batches each use seven full one-gallon jug cycles plus one half-gallon cycle; B13 uses four full cycles. Each full jug takes two 0.5-gal scoop fills and each half jug one; 188 scoop fills supply 88 full plus 12 half jug cycles =100 cycles and 94 gal. Each full pour takes at least 30 seconds and each half pour at least 15 seconds to respect the assumed maximum 2 GPM; pause for splash, backup or overflow risk. The 100-minute transfer budget includes controlled pours and handling, separately from 39 minutes for thirteen drain/resets. Story outcome: 13 accepted batches, 0 overflow, 0 bypass and 0 rejected batch. S01 serves B01–B06 and S02 B07–B13; no treatment capacity is proven. SW01 driveway debris, SW02 patio debris, SW03 used inserts/screenings and SW04 pads/tape remain in four segregated closed ordinary-waste bags for the assumed accepted solid-waste route. No real receipt or weight is claimed.
Status fallback and next action
SIMULATED Day 0 T + 275 closeout: completed transfers and four solids bags accounted for; no disposal exception remains in the story. HOLD actual work if dimensions, individual load, capture, draining, jug transfer, receiving acceptance or complete-cycle timing cannot be safely verified. Stop for escape, changed waste, blocked receptor, lost power/pickup, public entry, splash or overflow risk. AUTH-P-01, its rates, dimensions, quantities and performance are all invented; no alternate storm, lawn or septic route is authorized.

References: PT21, PT22, PT08, PT09, PT23. Read the scope and exact product instructions.

Check your work

  • A customer cannot authorize utility discharge alone.
  • Approval is site- and waste-specific.
  • Containment failure stops generation.
  • The complete physical transfer path, supported geometry, safe individual load, rate, counts and time are documented; authorization alone does not prove feasibility.

Related lessons

Export saves only this page as text. Web entries do not synchronize with the downloadable workbook or another device. These educational records are not official filings or a universal legal contract.